[ Up ]
|

 |
H25-IR
Industrial Refrigerant Leak Detector
The
H25-IR is an industrial leak detector used for low-level detection and leak rate
quantification of CFCs, HFCs, HCFCs and halogen gas compounds that are used in
air conditioning and refrigeration equipment, fire suppression systems, and
various other residential, commercial and industrial apparatus. The instrument
can be used to locate and quantify leaks as well as log and totalize the entire
group of leaks in a systems to ensure quality assurance compliance. The unit is
capable of detecting 29 of the most commonly used refrigerants and halogen gas
compounds.
|

Features & Benefits:
- Utilizes Infrared Technology for Detection -- ensures long sensor
life and high accuracy
- Fewer False Alarms -- use of infrared technology enables response
to refrigerants only
- Fast Response Time -- responds to leaks in less than 1 second
- High Sensitivity -- detects leaks as small as 0.01 oz/yr
- Internal Leak Source -- enables calibrations to be made quickly
and easily
- Logging -- enables the total leak rate of a system to be
quantified
- 8 Inch Flexible Probe -- enables leak checking in hard-to-reach
areas
- Adjustable Sensitivity Ranges -- enable “nuisance” leaks to be
ignored
- 4 Relay Outputs -- enables external alarm control
- 4–20 mA Output -- provides remote monitoring
- 2 Year Warranty

Specifications:
| Gases Measured |
R-11, R-12, R-22, R-23, R-113, R-114, R-123, R-124, R-134a,
R-227, R-236fa, R-401A, R-402A, R-402B, R-404A, R-407A, R-407C, R-408A,
R-409A, R-410A, R-500, R-502, R-503, R-507,
R-508B, H-1211, H-1301, H-2402, N-1230 |
| Sensor |
Infrared |
| Measurement Units |
oz/yr, g/yr, mL/s, PaM3/s, ppm |
Measurement
Range & Accuracy |
0–50 oz/yr, ±10% of reading
50–1000 oz/yr, ±25% of reading |
| Warm-Up Time |
2 minutes |
| Probe |
8" (20.3 cm) flexible probe with 6' (1.8 m) or optional
12' (3.6 m) hose |
| Operating Modes |
Search -- detects presence and location
of gas leaks; Measure -- calculates and displays leak rate |
| Response Time |
Less than 1 second (with 6' hose) |
| Sensitivity |
0.01 oz/yr for most gases (minimum of 0.03 oz/yr for
all gases) |
| Temperature Drift |
±0.8% of reading per °C |
| Calibration |
Internal R-134a leak source, or External
using customer supplied leak source |
| AC Input |
100–240 VAC, 50/60 Hz |
| Power Consumption |
15 Watts |
| Operating Temperature Range |
32 to 122°F (0 to 50°C) |
| Storage Temperature Range |
–4 to 122°F (–20 to 50°C) |
| Weight |
18 lbs (8.2 kg) |
| Dimensions |
4"H x 10.75"W x 15"D (10.2 x 27.3 x 38.1 cm) |

Ordering Information
| Part Number |
Description |
| 3015-4420 |
H25-IR with 6' probe hose, 6' power cord and manual |
| 3015-4417 |
H25-IR with 12' probe hose, 6' power cord and manual |
| 3015-1486 |
15.5" flexible probe (optional) |
| 3015-1018 |
Internal particulate filter |

Additional Product Information
(3.70MB) Data Sheet
(2500K) Instruction Manual
(577K) Optical Bench Replacement Instructions
(776K) Refrigerant Recovery Systems & HVAC Service
Tools/Accessories
|