HGM300-RDM800
Refrigerant Gas Multi-Zone Monitor with Remote Display
The HGM300 Multi-Zone Refrigerant Monitor, and the RDM800 Remote Display Module combine to provide a multi-zone refrigerant gas monitoring system.
Features & Benefits
- Select areas to be measured - point by point
- Eliminate false alarms with use of non-dispersive IR source and sample draw system
- Measures all refrigerant gases up to 10,000 ppm with a sensitivity of 1 ppm
- Sample points locate up to 500 feet from unit
- Remotely interrogate, acknowledge alarms
- Quick field expansion from 4 to 16 sampling zones
- Bolt-in, bolt-out internal components so the unit never leaves the wall
- Full two-way communication via RS-458
- RS-232 port for local / modem communication
- Split-architecture design keeps your investment to a minimum
- Two-year warranty
Specifications
- Gases Monitored:
- CFC: R 11, R 12, R 113, R 114, R 502, R 404a (HP62), R 407a, R 407c (AC9000), R 134a, R 410a (AZ20), R 507 (AZ50), R 508b (SUVA95)
- HCFC: R 22, R 123, R 124, R 500, R 503, R 401a (MP39), R 402a (HP80), R 40b (HP81), R 408a, R 409a, R 23
- HALON: 1301
- Measuring Range: All gases 0 to 10,000 ppm
- Inputs: 4 points standard, expandable to 16 points in 4 point increments
- Output Signal: 4–20 mA DC (optional)
- Detector Type: Non-dispersive infrared
- Sensitivity: All gases 1 ppm
- Accuracy: All gases ±10 ppm from 0 to 100 ppm, ±10% of reading from 100 to 10,000 ppm
- Front Panel Display:
- Green LED indicates when unit is operating properly
- Red LED indicates when any monitored point is above its alarm setting
- Yellow LED indicates a clogged sample line or other system fault
- Response Time: 5 to 120 seconds, depending on tube length and gas concentration
- Monitoring Distance: Up to 500 feet from measuring point to monitor
- Power: 120/240 VAC, 50/60 Hz
- Size/Weight: 17" x 12" x 5.5" / 15 lbs (may be wall or rack mounted)
HGM300 Monitor Ordering Information
When ordering this product, you must specify 3 codes. These codes will build up a part number. Codes must be listed in the following sequence:
- Code A - Model Number
- Code B - Number of Zones
- Code C - AC Input Power
For example: To order a 4-zone, 120 VAC refrigerant monitor, you would order a HGM300-11-1.
| Code A | Model Number |
| HGM300 | Refrigerant Gas Monitor |
| Code B | Number of Zones |
| -11 | 4 Zones |
| -12 | 8 Zones |
| -13 | 12 Zones |
| -14 | 16 Zones |
| Code C | AC Input Power |
| -1 | 120 VAC / 60 Hz |
| -2 | 240 VAC / 50 Hz |
| -3 | 240 VAC / 60 Hz (Domestic Applications Only) |
RDM800 Remote Display Ordering Information
| Part Number | Description |
| 3015-2875 | RDM800 120 VAC / 60 Hz |
| 3015-2885 | RDM800 240 VAC / 50 Hz |
Ordering Information
| Part Number | Description |
| 3015-4121 | 120 VAC surge protection |
| 3015-4123 | 4-20 mA dc surge protection (two required) |
| 3015-3133 | Dual 4-20 mA dc output kit |
| 3015-3069 | Visual alarm 120 VAC |
| 3015-3070 | Audible alarm 120 VAC |
| 3015-3076 | Audible / Visual alarm 120 VAC |
| 3015-3423 | Annual maintenance kit |
| 3015-3235 | Air tubing (250 ft roll) |
|