H-10PA

Click for Purchase Information

Refrigerant Leak Detector

H-10PA Refrigerant Leak Detector

Features & Benefits

  • All the powerful features of the H-10PM, but powered from an external 12VDC source
  • Finding all the repairable leaks in an AC system with sensitivity ratings exceeding SAE J1627
  • An unsurpassed value for capability and price
  • CE Mark

Specifications

  • Detects: All CFC, HFC, and HCFC Refrigerants
  • Sensing Element: Positive Ion Emission Heated Diode
  • Sensitivity: Moving probe test per SAE Std. J1627
  • Alarm Sensitivity:
    • R-134a
      • Moving Probe
        • Small - 0.5 oz/year
        • Medium - 1.0 oz/year
        • Large - 5.0 oz/year
      • Stationary Probe
        • Small - 0.1 oz/year
        • Medium - 0.5 oz/year
        • Large - 2.0 oz/year
    • R-12
      • Small - 0.1 oz/year
      • Medium - 0.5 oz/year
      • Large - 3.0 oz/year
  • Warm-Up Time: Approx. 2 minutes
  • Accuracy: Exceeds SAE J1627
  • Probe Length: 4.5 feet
  • Dimensions: 5.5" x 10.5" x 8.5"
  • Weight: Approx. 3 lbs
  • Agency Listings: UL file SA9717, SAE J1627, CE-Mark
  • Power: 12 VDC or optional 120 VAC wall adapter
  • Leak Alarm: Audible alarm and visible neon lamp
  • Response Time: Approx. 1 sec.