GDX-350

Click for Purchase Information

Gas Sensor Transmitter/Monitor

GDX-350

Bacharach’s all new state-of-the-art GDX-350 low temperature transmitters with B-Smart® technology
provide accurate detection of ammonia (NH3) and carbon dioxide (CO2). These full featured standalone
transmitters are designed to operate in extreme temperature conditions found in blast chillers and deep
freezers. GDX-350’s unique design includes programmable heaters for both the sensor and electronics
that are automatically activated when temperatures drop below user selectable temperatures. Placing
the sensors inside these harsh operating environments allow for quick detection and response to the
smallest leaks, protecting human life as well as product and machinery.

Features & Benefits

  • Non-Dispersive Infrared (NDIR) CO2 detection range of 0-5%
  • Electrochemical sensors for detecting 0-500 ppm of Ammonia
  • Heated sensors and electronics for low temperature operation (-55 degrees Celsius)
  • Graphic LCD for real time monitoring of concentrations
  • 4-20 mA and optional Modbus® RTU interface
  • 30 minute onboard data trend
  • B-Smart® sensor program
  • Optional Relay outputs

B-Smart® Sensors

The B-Smart® Sensor Exchange Program allows users to replace pre-calibrated sensors in the field, eliminating the need to send it in for calibration. With the B-Smart® Sensor Program, you receive factory-calibrated sensors, just plug them in and continue to use your instrument – there’s no down time and it saves time and money.

Specifications

Detection Principle Infrared, Field Replaceable (CO2), Electrochemical (NH3)
Measuring Range CO2: 0 - 5%, in .1% Increments
NH3: 0-500 ppm, in 1 ppm Increments
Dimensions 8.0” x 5.5” x 4.61” (20.32 cm x 13.97 cm x 11.709 cm)
Housing Durable Aluminum Enclosure Suitable for Class 1, Div 1&2,
Gr. B,C,D
Front Panel 5 Indicator Lights; AL1, AL2, Fail, In Cal and RS-485
User Interface 64 x 128 Pixel LCD Graphic Display for Gas Readings, 30 Minute Trend, Bar Graphing, Engineering Units and Backlight
Operating Temperature Range -67 to 140°F (-55 to 60°C)
Ambient Humidity Range 5% to 90% RH Non-Condensing
Response Time CO2: T50 <15 s , T90 < 30s
NH3: T50 <30 s , T90 < 90s
Security Mode Lock Out Critical Parameters
4-20 Output Signal 3-Wire, 4-20 mA. Max Loop Resistance is 750 ohms (@24 VDC)
Alarm Relays Three Configurable Form C (SPDT) Relays Rated for 5 amp at 30 VDC or 240 ~VAC RESISTIVE.
Relay 1 and Relay 2 Level Alarms are Configurable for HIGH or LOW Trip, for Normally Energized (Failsafe) or Normally De-Energized and for Latching or Non-Latching.
Relay 3 is Always Normally Energized for Failsafe Operation so Loss of Power to GDX-350 will be Indicated as a “FAULT” Condition.
Communications RS-485, Modbus®
Power 10 - 30 VDC, 250 mA (@ 24 VDC)
Power Safety Mode Fully Automatic System Reset – All Programmed Parameters Retained
Approvals CSA: Division 1 & 2, Class 1 Groups B,C,D (for CO2 only)
ATEX: CE Mark, EExd IIB + H2, T5 (for CO2 only)

Ordering Information

Part Number Description
5600-3224 GDX-350 CO2 Transmitter with Relays and Modbus® RTU Interface
5600-3223 GDX-350 CO2 Transmitter without Relays and Modbus® RTU Interface
5600-3054 GDX-350 NH3 Transmitter with Relays and Modbus® RTU Interface
5600-3053 GDX-350 NH3 Transmitter without Relays and Modbus® RTU Interface

Replacement Parts & Accessories

Part NumberDescription
5600-0004GDX Calibration Cup/Sample Draw Adaptor
5600-0003 GDX Splash Guard/Remote Cal-Cup
0024-7059 Calibration Kit – Regulator, Tubing, and Carrying Case (no gas included)
0051-3160 NH3 Calibration Gas, 25 ppm, 58 Liter
0054-0605 CO2 Calibration Gas, 2.0%Vol, 103 Liter
0051-7131 Zero Grade Air, 103 Liter
5600-5002 CO2 Replacement Sensor
5600-5003 NH3 Replacement Sensor
5600-6000 GDX-350 B-Smart® CO2 Sensor, Pre-Calibrated
5600-6001 GDX-350 B-Smart® NH3 Sensor, Pre-Calibrated
5600-8000 GDX-350 B-Smart® CO2 Sensor (2-year program/sensors replaced every 12 months)
5600-8001 GDX-350 B-Smart® NH3 Sensors (2-year program/sensors replaced every 6 months)